Coin Cell Lab Research Line

Electrode making
  • Baking active material
  • Mixing and grinding prepared baking material
  • Vacuum mixing positive and negative mixture
  • Measure the viscosity with a viscometer and record it for next time
  • Filtered particles and all hard particle which particle size not less than 124 microns
  • Coated positive and negative materials respectively on fluid collection and drying
  • Roll press the electrode to reduce thickness, increase density
  • Put electrode into drying oven and deep baking
Battery package
  • Cut the positive and negative plate and separator paper into small discs of specified diameter
  • Move the cutting pole, diaphragm, electrolyte and battery case into glove box(Water and oxygen content should be less than 11PPM)
  • Put the order in accordance with the battery assembly from the bottom of the stack and is filled with electrolyte: anode shell > flat pad metal lithium electrolyte amount > > the amount of electrolyte layer of cathode electrolyte separator amount > > the amount of electrolyte electrolyte > > the amount of flat pad cathode shell shrapnel
Battery testing
  • Use a battery analyzer to test the battery's capacitance and cycle aging
  • Measure the internal resistance of the battery with an internal resistance tester
We can supply all set of coin cell making machine(the chart as below contains all the devices that need to be used)